Tripp Lite SMART750USB ユーザーズマニュアル

ページ / 15
3
Quic
k Installation
Plug the UPS into an outlet
that doesn’t share a cir
cuit
with a hea
vy electrical load.*
An air conditioner
, r
efrigerator
, etc.
NOTE! after
you plug the UPS into a live
AC
outlet, the UPS will turn ON automati-
cally
.
See “ON/OFF” Button description in
the Basic Operation section if you want to
place the UPS in any mode other
than ON.
Plug y
our equipment into 
the UPS.
The
outlets will provide battery backup
and sur
ge protection; plug your computer
,
monitor and other critical devices here.*
The
outlets will provide sur
ge protection
only; plug your printer and other non-
essential devices here.
*
 Y
our UPS is designed to only support computer equipment.
Y
ou will overload the UPS if the total V
A
ratings for all the
equipment you connect to the (A) outlets exceeds the UPS’
s
Output Capacity (see Specifications). T
o
 find your equipment’
s
V
A
ratings, look on their nameplates. If the equipment is
listed in amps, multiply the number of amps by 120 to
determine V
A. (Example: 1 amp × 120 = 120 V
A). If you
ar
e unsur
e if you have overloaded the (A) outlets, run a
self-test (see “MUTE/TEST” Button description). 
B
A
1
2
1
B
A
2
Impor
tant Saf
ety Instructions
2
UPS Location 
W
arnings
• Install your UPS indoors, away from excess moisture or heat, dust or direct sunlight.
• For best performance, keep the indoor temperature between between 32º F and 104º F  
(0º C and 40º C).
• Leave adequate space around all sides of the UPS for proper ventilation.
UPS Connection 
W
a
rnings
• Connect your UPS directly to a properly grounded 
AC power outlet. Do not plug the UPS
into itself; this will damage the UPS.
• Do not modify the UPS’
s plug, and do not use an adapter that would eliminate the UPS’
s
ground connection.
• Do not use extension cords to connect the UPS to an 
AC outlet. 
Y
our warranty will be
voided if 
anything other than 
T
ripp Lite sur
ge suppressors are used to connect your UPS 
to an outlet.
• If the UPS receives power from a motor
-powered 
AC generator
, the generator must 
provide clean, filtered, computer
-grade output.
Equipment Connection 
W
a
rnings
• Do not use 
T
ripp Lite UPS Systems for life-support applications in which a malfunction 
or failure of a 
T
ripp Lite UPS System could cause failure or significantly alter the 
performance of a life-support device.
• Do not connect sur
ge suppressors or extension cords to the output of your UPS. 
This may
damage the UPS and will void the sur
ge suppressor and UPS warranties.
Batter
y W
a
rnings
• 
Y
our UPS does not require routine maintenance. Do not open your UPS for any reason.
There are no user
-serviceable parts inside.
• Because the batteries present a risk of electrical shock and burn from high short-circuit
current, observe proper precautions. Unplug and turn of
f the UPS before performing 
battery replacement. Use tools with insulated handles, and replace the existing batteries
with the same number and type of new batteries (Sealed Lead-Acid). Do not open the
batteries. Do not short or bridge the battery terminals with any object. 
T
ripp Lite of
fers a
complete line of UPS System Replacement Battery Cartridges (R.B.C.). 
V
isit 
T
ripp Lite
on the 
W
eb at www
.tripplite.com/support/battery/index.cfm to locate the specific 
replacement battery for your UPS.
• 
The UPS batteries are recyclable. Refer to local codes for disposal requirements, or in the
USA
only call 1-800-SA
V
-LEAD or 1-800-8-BA
TTER
Y
(1-800-8-228-8379) or visit
www
.rbrc.com for recycling information. Do not dispose of the batteries in a fire. 
• Do not attempt to add external batteries.
SA
VE THESE 
INSTR
UCTIONS
This manual contains instructions and warnings that should be followed during the 
installation, operation and storage of all 
T
ripp Lite UPS Systems. Failure to heed these
warnings will void your warranty
.