HP (Hewlett-Packard) E2A03UT#ABA ユーザーズマニュアル

ページ / 209
POST numeric codes and text messages
This section covers those POST errors that have numeric codes associated with them. The section also
includes some text messages that may be encountered during POST.
NOTE:
The computer will beep once after a POST text message is displayed on the screen.
Control panel message
Description
Recommended action
101-Option ROM Checksum Error
System ROM checksum.
1.
Verify the correct ROM.
2.
Flash the ROM if needed.
3.
Clear CMOS. (See Appendix B,
4.
Replace the system board.
103-System Board Failure
DMA or timers.
1.
Clear CMOS. (See Appendix B,
2.
Replace the system board.
162-System Options Not Set
Configuration incorrect.
RTC (real-time clock) battery may need to
be replaced.
Run Computer Setup and check the
configuration in Advanced > Onboard
Devices
.
Reset the date and time under Control
Panel
. If the problem persists, replace the
RTC battery. See the Removal and
Replacement section for instructions on
installing a new battery, or contact an
authorized dealer or reseller for RTC battery
replacement.
163-Time & Date Not Set
Invalid time or date in configuration memory.
RTC (real-time clock) battery may need to
be replaced.
Reset the date and time under Control
Panel
 (Computer Setup can also be used). If
the problem persists, replace the RTC
battery. See the Removal and Replacement
section for instructions on installing a new
battery, or contact an authorized dealer or
reseller for RTC battery replacement.
163-Time & Date Not Set
CMOS jumper may not be properly installed. Check for proper placement of the CMOS
jumper if applicable.
164-MemorySize Error
Memory amount has changed since the last
boot (memory added or removed).
Press the 
F1
 key to save the memory
changes.
178
Chapter 10   POST error messages