Oceanic GEO ユーザーズマニュアル

ページ / 140
87
No off gassing Credit will be given while above a Required
Stop Depth, and for each minute above it 1
1
/
minutes of
Penalty Time will be added to Required Stop Time and TAT
(Total Ascent Time).
The added Penalty (decompression) Time will have to be
worked off first, before obtaining off gassing credit will be
given.
Once the Penalty Time is worked off, and off gassing Credit
begins, required Deco Stop Depths and Time will decrease
toward zero.  The TLBG will recede into the No Deco Zone
and the GEO will revert to the No Deco Dive Mode.
NOTE:  Upon entry into the following Delayed
Violation Modes, the Audible Alarm will sound
and the red LED will flash  even if  Set OFF.
When these events occur, the Alarm cannot be
acknowledged/silenced by pressing the S
button.
DELAYED VIOLATION #1 (Fig. 83)
If you remain above the Required DECO Stop Depth for more
than 5 minutes, the full TLBG and DOWN Arrow will flash until
you descend below the Required Stop Depth.  Also, the
graphic message DOWN > TO > xxF (or xxM) will continue to
scroll. This is a continuation of a Conditional Violation.
Fig. 83 - DELAYED
VIOLATION #1 MAIN