Cognitive Solutions A776 ユーザーズマニュアル

ページ / 192
Chapter 5: Programming commands
68
A776 (B780) Programming Guide 
A776-PG00001 C 12/09
Select double-density graphics
ASCII 
ESC Y nnd1 ... dn 
Hexadecimal  1B 59 nnd1 ... d
Decimal 
27 89 nnd1 ... d
Equivalent to 1B  2A  m=1  nnd1 ... dn
Print Flash Logo
ASCII     
FS p n m 
Hexadecimal  1C 70 n m 
Decimal 
28 112 n m
Print flash logo ID n using mode m.  See command 1D 2F m for description of mode m.  See 
command 1C 71 for description of n. The select slip command x/C must be disabled via  
1F 03 38 00 to use this logo command.
Define Flash Logos
ASCII     
FS q n  [xL xH yL yH d1 …dk]1…[xL xH yL yH d1 …dk]
Hexadecimal     1C 71 n  [xL xH yL yH d1 …dk]1…[xL xH yL yH d1 …dk]
Decimal 
28 113 n  [xL xH yL yH d1 …dk]1…[xL xH yL yH d1 …dk]n
Define n flash logos specified by IDs 1 through n.  Maximum size of logos is determined by 
amount of flash allocated to logos.  See command 1D 22 80… for flash allocation.The select slip 
command x/C must be disabled via 1F 03 38 00 to use this logo command.
0 < xH:xL < 1024  max printable xH:xL = 72 = 576 dots wide
0 < yH:yL < 256
For each logo definition:  xH:xL times 8 dots in the horizontal direction, yH:yL times 8 dots 
in the vertical direction.  Total data definition bytes k = xH:xL times  yH:yL times 8 bytes.  See 
command 1D 2A x y … for description of data definition bytes arrangement.
During execution of this command printer turns off USM and Real Time status processing.  The 
printer goes busy when writing to flash.  At the end of this command the printer resets.
Select the current logo (downloaded bit image)
ASCII 
GS # n 
Hexadecimal  1D 23 n 
Decimal 
29 35 n
Range of n: 
0 – 255
Default:  
0 
Selects a color or monochrome logo to be defined or printed. The active logo n remains in use until this command is 
sent again with a different logo n.
When this command precedes a logo definition, that definition is stored in flash memory as logo n. If there is already 
a different definition in flash memory for logo n, the first is inactivated and the new definition is used. The inactive 
definition is not erased from flash and continues to take up space in flash memory.
When this command precedes a logo print command and n is different from the previously active logo selected, the 
printer retrieves the logo definition for n from flash memory and prints it. If there is no definition for logo n, then no 
logo is printed.
In the case of a previously existing application that expects only one possible logo, the printer will not receive the 
select current logo (1D 23 n) command. In this case, the printer assigns 0 as the active logo identifier. It automatically 
stores any new logo definition in flash memory as logo 0, inactivating any previous logo 0 definition. If the flash 
memory space available for logos fills up with inactive logo 0 definitions, the firmware erases the old definitions at the 
next power cycle. This is the only case in which the printer erases flash memory without an application command.
Continued . . .