STACK menu settings
Example:
Cover Error: The lamp cover is open.
Lamp Error: The lamp will not light up.
Fan Error: There is a problem with the cooling 
fan.
Temp Error: The temperature of the projector is 
too high.
Air Flow Error: The temperature of the 
projector is too high. Verify that the exhaust 
vents are not blocked.
Filter Error: The filter timer counter exceeds 
the hours set in the FILTER MESSAGE menu. 
(
Operating Guide
 → 
OPTION menu
 → 
SERVICE
)
Cold Error: The temperature around the 
projector is too low.
● If you need to turn off a projector in order to fix an error condition, turn off 
both the projectors so that Intelligent Stack can be started properly when the 
projectors are turned on again. 
● If the PIN LOCK or TRANSITION DETECTOR security function on both 
projectors is set to ON, both projectors will turn on. Enter the security code for 
Main first, then the security code for Sub. If ALTERNATE mode is selected, one 
of the projectors will turn off automatically. (
Operating Guide
 → 
SECURITY 
menu
)
● If the PIN LOCK or TRANSITION DETECTOR security function on one of the 
projectors is set to ON, it is necessary to enter the security code as follows 
when turning on the projector: 
-  In DUAL mode, both projectors will turn on. Enter the security code for the 
projector that is locked by the security function. 
-  In ALTERNATE mode, if the projector locked by the security function is due 
to turn on according to the ALTERNATE mode setting, only that projector will 
turn on. Otherwise, both projectors will turn on. Enter the security code for 
the projector that is locked by the security function. After the security lock is 
released, one of the projectors will turn off if both projectors are turned on. 
3.7 Important information for Intelligent Stack 