Extron electronic PCM 240 ユーザーズマニュアル

ページ / 4
2
PCM 240 • Installation Guide (Continued)
f. 
Using these dimensions, mark and cut a hole (using a 2 inch hole saw) for 
the projector pipe in the removed ceiling tile (see figure 3).
g. 
If required, to prepare the ceiling tile for a power outlet, use the PCM 
plate to trace and cut out the 2-gang hole in the ceiling tile for a  
UL approved RACO
®
 junction box. 
If this is not required, proceed to step 3.
Step 2 — Install the Electrical Box.
The following method is recommended for integrating a RACO electrical box 
(not supplied) on the PCM base plate. A RACO box (#8471), an MK box, or 
standard UL electrical boxes can be inserted.  Mounting holes for Extron 
3 inch deep, ¼ rack wide devices are also included.
Install the RACO box on the PCM plate as follows:
a. 
Attach the box to the plate, using the smallest notches in opposite corners 
of the cut-out. Do not tighten the screws fully at this time.
b. 
On the room side of the tile, slide the plaster ring under the screws
c. 
Fully tighten the screws 
WARNING: 
Risk of Personal Injury. For safety, complete all wiring 
of the electrical boxes and accessories after the plate 
is installed and secure. 
All electrical installation should be done by a qualified 
electrician.
Step 3 — Secure the PCM Base Plate to the Ceiling.
Tie wire installation
a. 
Replace the cut ceiling tile, checking the orientation.
b. 
Replace the PCM base plate over the ceiling tile and align the hole with 
the PCM adapter plate.
c. 
Attach the four turnbuckles to the mounting plate, one at each corner.
ATTENTION: 
Risk of Personal Injury and property damage. 
• DO NOT rest or lean on the mounting plate or 
   suspended ceiling when attaching the turnbuckles 
   and tie wire, or when drilling into the ceiling.
  
• For safest installation, insert the turnbuckle from  
   the outside so that it hooks inwards.
d. 
Mark and drill four holes, approximately 1¼ inch (32 mm) deep into the 
ceiling joists, using a 1/4 inch (6.4 mm) diameter drill bit. Do this at 10 
degrees out from vertical. Drill a fifth hole centered above the PCM for 
the safety cable (see figure 5). Minimum suitable joist size should be 
2 inches by 4 inches.
e. 
Install appropriate anchors or lag eye bolts for the structural ceiling into 
each drilled hole.
Attach turnbuckles 
to long sides.
T-bar Securing 
Screws
Pipe Adapter Plate 
Lock Nuts
10
Attach ceiling 
anchors and wire
10 degrees from 
vertical.
T-bar
Mounting Plate
Underside
Top Side
Figure 3. 
Mark and start cutting on 
underside.  Finish on top 
side.
Figure 4. 
RACO and MK Box 
Installation Points.
Figure 5. 
Attach Tie Wire and Safety 
Cable.
1-gang and 2-gang
Electrical Box Cut-outs
3" Deep, ¼ Rack
Device Mounting Holes
Raco and MK Box Cut-out