6.1 
RS-232 Connection 
and Port Configuration
To interface the VX-33i with a home theater automation/control system or a PC running 
terminal emulation software, connect it to your control system or PC as shown in Figure 
3-15
Use a null-modem cable. 
If you are using a PC to communicate with the VX-33i: 
1.
Start a terminal session on your PC using a terminal-emulation program, such as 
HyperTerminal. 
2.
Configure the PC serial port as follows: no parity, 8 data bits, 1 stop bit and no flow 
control. Set the baud rate to 19200, to match that of the VX-33i RS-232 port.
3.
Press 
<Enter>. You should see a command prompt (>) in the terminal window. 
4.
Type a command from among those listed in Table 6-1 and press 
<Enter>. 
6.2 
Serial Command 
Syntax
• Commands are in ASCII format and are not case-sensitive; 
on and ON are equivalent. 
• For a command that takes no parameters, type the command followed by a carriage 
return; for example, to turn on the system, type 
ON<Enter>
• For a command that takes a parameter, type the command, one or more spaces and 
the desired value followed by a carriage return; for example, to switch to the S-Video 
input, type 
SSRC 1<Enter>
• When you enter a valid command, the VX-33i executes it. When you send an on/off, 
input selection, aspect ratio or image preset command, the VX-33i also responds with 
an acknowledgment on the command line. For example, when you issue the command 
SAR 2, the VX-33i responds with Letterbox on the command line. 
• When you enter a misspelled or otherwise invalid command, the VX-33i ignores it and 
responds with 
Invalid Command on the command line. 
• When you send a command followed by values outside the valid range for that 
command, the VX-33i ignores it and responds with 
Invalid Parameter on the 
command line.
• When the VX-33i receives an 
OFF command, it will not acknowledge or execute any 
commands for approximately 90 seconds afterwards. This is to prevent hot re-strikes 
of the lamp, which can damage it.
• After sending an 
ON command, allow at least 30 seconds for the projector to warm up 
before sending another command. 
6. Serial Communications