AudioQuest M-27 ユーザーズマニュアル

ページ / 25
 
.
 
 
 
.61 is the percent dose accumulated at 80 dB.  
 
1.23 is the percent at 81 dB, etc. 
 
The percent dose statistical distribution is accumulated without a threshold. Of course, the dose 
calculations in the summary exclude any dose accumulated below the threshold. 
 
The graph is similar to the % TIME graph. 
 
If the internal TEXT or GRAPH switch is off, that portion will not be printed. 
 
3 dB Only Systems 
 
The previous examples illustrated the M-27 when used with two different exchange rates. It can be 
used as a 3 dB only system with three different histograms, one with no threshold and two with thresholds. 
It will also print four statistical distributions, two with a Time constant and two without. If the M-27 is used 
for community or 3 dB industrial monitoring, the printout will contain much more information than would 
a data logger with a single printout. 
 
NOTE 
If the criterion level is set to 85 dB, then the dose reading can be easily converted to Pascal squared hours. 
For a 3 dB system with a 85 dB criterion level, a 100% dose is equal to 1 Pascal squared hour. To 
calculate the exposure in Pascal squared hours, divide the dose by 100
 
Dump Data 
 
If the CODE/HL3 is cycled until the display shows CPU, raw data may be dumped to a computer 
when PRINT is pressed. Each line contains an address and 16 bytes of memory starting at that address (see 
Figure 16). 
 
See Memory Map section for a description of the data. 
 
General
 
When printing, the M-27 remembers which keys have been pressed