Setting System Security Parameters
The MERLIN Messaging System provides the following features to help protect your system
against toll fraud:
Transfer Restrictions – When this feature is activated, *8 transfers, Automated
Attendant direct extension transfers are restricted to extensions that are included in the
MERLIN Messaging System extension list. The extension list includes extensions
assigned as Automated Attendant extensions, Mailbox extensions, Transfer– Only
extensions and Fax extensions.The Transfer Restriction setting does not apply to Call
Answer Service Operator extensions, Selector Code Transfer extensions and Dial
0/Timeout extensions. Make sure the extensions for these items are valid before you
begin the system administration procedures.
Security Alert – Setting a minimum password length of six digits or greater is highly
recommended to help discourage hackers. If you choose a setting of less than six digits,
the system reminds you that a setting of six or more digits makes your system less
vulnerable to toll fraud.
Minimum Password Length – is the minimum number of digits users must enter when
setting a new password for their mailbox. The factory setting is six digits; this setting
can be changed to 0 – 15 digits.
Note:
Refer to MERLIN Messaging System Planning Form 5 – Security Settings for the
site-specific information you need to complete the following programming tasks.