Lucent Technologies merlin messaging system ユーザーズマニュアル

ページ / 476
Providing Overflow Coverage to MERLIN Messaging System for the Delayed Call Handling
Calling Group
Use this procedure to do the following:
Specify the MERLIN Messaging System Calling Group as the overflow receiver for the Delayed Call
Handling Calling Group.
●   
Change the factory setting for the Number-Based Overflow from 1 to 99 calls.
●   
Set the Time-Based Overflow threshold to the appropriate setting (approximately 5 seconds for each
ring). For example, if you want a call to ring at the DLC System Operator's position 5 times before
being transferred, set the Time-Based Overflow to 25 seconds.
●   
Note:
Keep the factory settings for the Calling Group type
(AutoLogout) and hunt type (circular).
 
[nnn]
Step Programming Task
Console Input/Selection
PC Input/Selection
1
Enter programming mode
 Sys Program
 Exit/Start
 
[any
key]
2
Select Extensions
Extensions
3
Display next page of menu
4
Select Group Calling
 Grp Calling
5
Select Overflow
 Overflow
6
Enter extension number of Delayed
Call Handling Calling Group
[nnn]
 Enter
[nnn]
7
Erase current overflow receiver
extension, if assigned
 Drop
 + 
8
Enter extension for the MERLIN
Messaging System Calling Group
[nnn]
 Enter
[nnn]
9
Select Number-Based Overflow
 Number Based
Overflow
10
Erase the current number of calls
 Drop
 + 
11
Enter the highest setting (to ensure
calls go to overflow based on time
and not number of calls)
[99]
 Enter
[99]
12
Select Time-Based Overflow
 Time Based
Overflow
Providing Overflow Coverage to MERLIN Messaging System for the Delayed Call Handling Calling Group
http://www.sostc.com/lucent/installation/programming_the_communication_system/provovercov.htm (1 of 2) [2/2/2000 2:33:43 PM]