Alcatel Carrier Internetworking Solutions OmniAccess 8550 ユーザーズマニュアル
www.alcatel-lucent.com
Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other
trademarks are the property of their respective owners. Alcatel-Lucent assumes no responsibility for
the accuracy of the information presented, which is subject to change without notice.
© 2008 Alcatel-Lucent. All rights reserved. P/N 031953-00 Rev C 10/08
trademarks are the property of their respective owners. Alcatel-Lucent assumes no responsibility for
the accuracy of the information presented, which is subject to change without notice.
© 2008 Alcatel-Lucent. All rights reserved. P/N 031953-00 Rev C 10/08
System configuration
The Alcatel-Lucent OmniAccess 8550 WSG is a
high–performance, 2U, rack-mountable network
element consisting of:
high–performance, 2U, rack-mountable network
element consisting of:
• Two Quad-Core Intel E5345 Xeon processors
(2.33 GHz, 80 watts, 1333 FSB), each with 8
MB of L2 cache
MB of L2 cache
• 8 GB of CPU memory with advanced ECC
(multi-bit error) protection
• 146 GB hot-pluggable hard drives with RAID1
SAS disk array
• Fully redundant power supplies
• Fully redundant fans
• Six 10BaseT/100BaseTX/1000BaseTX network
interfaces that support bonding for redundancy
• Built-in high-performance SSL/TLS and crypto-
graphic hardware
• Built-in high-performance XML processing
hardware
• Front panel hardware alarm indicators
• Includes universal rail kit for 19-inch racks
Physical dimensions
• Height: 3.38 in. (8.59 cm.)
• Width: 17.54 in. (44.54 cm)
• Depth: 23.65 in. (60.07 cm)
• Weight: 60 lb (27.22 kg)
Power Specifications
• Input (per power supply)
¬ Line voltage: 100 VAC - 132 VAC
200 VAC - 240 VAC
¬ Input current: 3.3 A (at 120 VAC)
2.3 A (at 220 V AC)
¬ Input power: 370 W (at 120 VAC)
470 W (at 220 VAC)
• BTU rating max: 1272 (for 120 VAC)
1610 (for 220 VAC)
Standards compliance
• WSRM 1.1
• WSS 1.0
• WSS-Signature
• WSS-Encryption
• WS-Trust
• WSSE 1.0
• WSDL 1.1
• SOAP 1.1/1.2
• XSLT 1.0
• XPath 1.0
• UDDI 3.0
• HTTP 1.0/1.1
• TLSv1/SSLv3
• DES, 3DES, AES, RC4, SHA-1, MD5, PKCS #10,
X.509, RSA, DSA
• LDAP 3.0
• SAML 1.1
• SNMP
• SFTP
• IEEE 802.3, 802.3u, 802.3ab
Regulatory
E
EM
M C
C
ICES-003
Interference causing equipment standard for digital apparatus
FCC Part 15 Class B
FCC rules for radio frequency devices under FCC 15 of the rules of FCC
EN55022, Class A/B
Information technology equipment (ITE) - Radio disturbance characteristics - Limits and methods of
measurement - Class A/B
measurement - Class A/B
EN55024
ITE - Immunity characteristics - Limits and methods of measurements
CISPR 24
ITE - Immunity characteristics - Limits and methods of measurements
AS/NZS CISPR22
Limits and methods of measurement of radio disturbance characteristics of information
technology equipment
technology equipment
S
Sa
a ffe
e ttyy
CAN/CSA C22.2 No 60950-1-03 / UL 60950-1
ITE - Safety - Part 1: General Requirements
FDA 21 CFR 1040
Performance Standard for Light-Emitting Products
IEC 60825-1 (2001)
Safety of laser products - Part 1: Equipment classification, requirements and user's guide.
IEC 60825-2 (2000-05)
Safety of laser products - Part 2: Safety of optical fiber communication systems
EN60950-1
Safety of information technology equipment
IEC 60950-1
Information technology equipment - Safety - Part 1: General requirements
AS/NZS 60950-1:2001
Approval and test specification - Safety of information technology equipment including electrical
business equipment
business equipment
TTe
ell e
ecco
o m
m
IEEE 802.3
Carrier Sense Multiple Access with Collision Detection (CSMA/CD) access method and
PHY Layer Specification
PHY Layer Specification
E
EC
C D
Diirre
e ccttii vve
ess
ROHS 2002/95/EC
Directive 2002/95/EC of the European Parliament and of the Council of 27 January 2003 on the Restriction of the use
of certain Hazardous Substances in Electrical and Electronic Equipment (ROHS)
of certain Hazardous Substances in Electrical and Electronic Equipment (ROHS)
Technical specifications