Patton electronic 3120 ユーザーズマニュアル

ページ / 75
Configuring the RAS with a Web browser
45
Model 3120 RAS Getting Started Guide 
3 • Configuring the RAS for operation
14. Click on 
Submit
.
signaling is now configured for MFC-R2.
Note
The information entered into the Interregister Signaling section must 
match the information the telco provided. If the information entered 
is not the same, the RAS may not answer calls. In some installations, 
the phone company will send a special tone to alert that it is done 
sending the Calling Number. In this case, the value in the Total Dig-
its box does not have to match the telephone company’s exactly.
Channel assignment
This section describes configuring the RAS so it will know which channels are active. Do the following:
1. Select 
T1/E1 Link
 on the 
Configuration Menu
. The T1/E1 Link Activity window appears (see figure 28 on 
2. Click on 
Channel Assignment
. The WAN Circuit Channel Assignment window appears (see figure 33).
Figure 33. WAN Circuit Channel Assignment window
3. Click on the 
Dialin
 button located under 
Set all channels to:
.
4. Click on 
Submit Query
.
Configuring line settings and signaling for T1
1. Select 
T1/E1 Link
 on the 
Configuration Menu
. The T1/E1 Link Activity window appears (see figure 28 on 
2.
Link: 1
 corresponds to Line 1 on the RAS. This is the primary link for dial-in callers. Under Link 1, Click 
on 
Configuration
 then 
Modify
. The Line Interface Settings section of the WAN Circuit Configuration