Multi-Tech Systems MT5600SMI-XL92 ユーザーズマニュアル

ページ / 134
Chapter 5 – AT Commands, S-Registers, and Result Codes
Multi-Tech Systems, Inc. SocketModem MT5600SMI Developer’s Guide 
55
Error Control Commands
Command:
+ES
Error Control and Synchronous Mode Selection
Description:
This extended-format command specifies the initial requested mode of
operation when the modem is operating as the originator. Optionally
specifies the acceptable fallback mode of operation when the modem is
operating as the originator, and optionally specifies the acceptable fallback
mode of operation when the modem is operating as the answerer. Accepts
three numeric subparameters.
Default:
Varies by request
Defined Values:
<orig_rqst>
Decimal number specifies the initial requested mode of operation when the
modem is operating as the originator. The options are:
+ES0  Initiate call with Direct Mode.
+ES1  Initiate call with Normal Mode (also referred to as Buffered Mode)
only.
+ES2  Initiate V.42 without Detection Phase. If V.8 is in use, disable V.42
Detection Phase.
+ES3  Initiate V.42 with Detection Phase. (Default.)
+ES4 Initiate 
MNP.
+ES6  Initiate V.80 Synchronous Access Mode when connection is
completed, and Data State is entered. (See +ESA and +ITF
commands.)
+ES7  Initiate Frame Tunneling Mode when connection is complete, and
Data Mode is entered.
<orig_fbk>
Decimal number specifies the acceptable fallback mode of operation when
the modem is operating as the originator.
+ES0  LAPM, MNP, or Normal Mode error control optional. (Default.)
+ES1  LAPM, MNP, or Direct Mode error control optional.
+ES2  LAPM or MNP error control required; disconnect if error control is
not established.
+ES3  LAPM error control required; disconnect if error control is not
established.
+ES4  MNP error control required; disconnect if error control is not
established.
<ans_fbk>
Decimal number specifies the acceptable fallback mode of operation when
the modem is operating as the answerer or specifies V.80 Synchronous
Access Mode.
+ES0 Direct 
Mode.
+ES1  Error control disabled, use Normal Mode.
+ES2  LAPM, MNP, or Normal Mode error control optional. (Default.)
+ES3  LAPM, MNP, or Direct Mode error control optional.
+ES4  LAPM or MNP error control required; disconnect if error control is
not established.
+ES5  LAPM error control required; disconnect if error control is not
established.
+ES6  MNP error control required; disconnect if error control is not
established.
+ES8  Initiate V.80 Synchronous Access Mode when connection is
completed and Data State is entered (see +ESA and +ITF).
+ES9  Initiate Frame Tunneling Mode when connection is complete, and
Data Mode is entered.
Examples:
+ES=6 
Enable V.80 Synchronous Access Mode originator.
+ES=6 
Enable V.80 Synchronous Access Mode originator.
+ES=,,8 