PILOT ADJUSTMENT
The pilot flame can be observed by opening the pilot lighting
hole cover.  The pilot flame should surround the top 3/8 to ½
inch of the thermocouple (see Figure 2).  If the flame needs
adjusting, first locate the pilot adjustment screw cap and remove.
Adjustment screw is underneath (see Figure 1).  To increase the
flame, turn the pilot adjustment screw counterclockwise          .
To decrease the flame, turn the screw clockwise           .  NOTE:
The pilot is unregulated.  If incoming line pressure is more than
7” w.c. Natural Gas or 11” w.c. for L.P. Gas, the pilot flame size
should be decreased.
PILOT FLAME
ADJUST-
MENT
Pilot flame
should
envelop
 3/8 to 1/2
 inch on the
 tip of the
generator.
FIGURE 2
RADIANTS AND GLASS PANELS
FOR ALL VCR MODELS
(See Figure 9 – Replacement Parts Section)
INSTALL GLASS AND RADIANTS AS FOLLOWS:
STEP 1. Remove three screws from under top of opening in
bezel frame assembly.
STEP 2. Pull top of bezel down and lay aside.
STEP 3. Remove glass from bottom pad in shipping carton.
STEP 4. Remove carton containing radiants from cavity of
combustion chamber.
STEP 5. Remove radiants from carton and install by tilting
backwards and lifting at the same time into opening.  Place
the radiants on the burner radiants supports.  The radiants
must be straight.  Never operate heater if any radiant is
tilted to front or rear.
Continued
STEP 6. Install glass panels by inserting top edge into upper
retainer and lower into bottom support, and slide glass into
position.  Do not allow a crack between the two glass panels.
Never operate heater with either glass missing or cracked.
STEP 7. Re-install bezel by placing bezel tabs over lower front
and swing bezel into position and secure with three screws.
MAIN BURNER ORIFICE
This appliance was shipped from the factory with an orifice
sized to give the correct gas input using the gas for which the
heater was equipped.  There may be local conditions, such as
variation in gas pressure or BTU content of the gas, which
may be cause for a change in the orifice.  The gas company
supplying the fuel or the installing contractor should check
the gas input rate.
If the rate exceeds the “BTUH INPUT” on the rating plate by
5%, the orifice should be replaced with a smaller orifice by a
qualified technician to reduce the input to the rating plate
value.
The input rate may need to be adjusted for elevation.  See the
following charts to determine the correct orifice size for your
Model Number and elevation.  These orifice sizes are based
on a heating value of 1020 for Natural Gas and 2500 for L.P.
Gas.
CAUTION:  As elevation increases, derating is necessary for
the safe and proper operation of this heater.  Do not increase
the Btu input rate by increasing the orifice size or gas
pressure.  Allow for elevation derating when sizing gas heating
equipment.
SPECIFIC ELEVATIONS
Model        0 to      2,000-      4,000 -      6,000 -      8,000’
 No.        2,000’      4,000’     6,000’       8,000’     10,000’
VC201         45
      47             48              49
 50
VC351         35              37             38              40
 42
VC501         30
      31             31              32
 35
VC701         25
      27             28              29
 30
VCR351       35
      37             38              40
 42
VCR501       30
      31             31              32
 35
VCR701       25
      27             28              29
 30
ORDER KIT #49820  45-1 HIGH ALTITUDE KIT
SPECIFIC ELEVATIONS
Model        0 to       2,000-
    4,000 -        6,000 -        8,000’
No.          2,000’      4,000’         6,000’        8,000’       10,000’
VC202     1.3mm
       55
          56            56
57
VC352    1.65mm        53
          53            54
54
VC502         47
       49
          49            50
51
VC702         41
       42
          43            44
46
VCR352   1.65mm        53
          53            54
54
VCR502      47
       49
          49            50
51
VCR702      41
       42
          43            44
46
ORDER KIT #49820  45-1 HIGH ALTITUDE KIT
NATURAL GAS