LISTINGS AND CODE APPROVALS
THE BUILDERS BOX SERIES HAS BEEN TESTED AND APPROVED IN ACCORDANCE WITH THE
CSA 
xxxxxxx
  No.
xxxxxxx
 STANDARDS FOR FIXED AND LOCATION
DEDICATED ELECTRIC ROOM HEATERS.
                        
MODEL SPECIFICATIONS
MODEL
NUMBER
DESCRIPTION
VOLTAGE
RATED POWER 
WATTS
REMOTE
CONTROL
AMPS
33EB304AAS
33” STANDARD
120/208/240
1440/2100/2700
YES
12.00/10.10/11.25
39EB364AAS
39” STANDARD
120/208/240
1440/2100/2700
YES
12.00/10.10/11.25
!!! WARNING !!!
THE INSTALLATION OF THE FIREPLACE UNIT MUST COMPLY WITH THE APPLICABLE
LOCAL AND/ OR NATIONAL ELECTRICAL CODES AND UTILITY REQUIREMENTS.
THIS INSTALLATION SHOULD BE ENTRUSTED TO DULY QUALIFIED
PERSONNEL WHERE REQUIRED BY LAW.
!POWER SELECTION WARNING!
This unit is factory wired for 110 volt power supply.
If 208/240 volt operation is required, slide the voltage switch
and reconfigure the wiring accordingly (see figure 2).
Wires L1, L2, N & G are attached to the rear of
the junction box for easy access.
!
!
1) Rough in framing following the
  recommended dimensions. (see figure 1)
2) Allow at least 8” of service cable for 
  connecting power supply wire to junction 
box on fireplace insert when installing
  before finishing wall. Allow up to 4 feet of 
service cable for connecting power supply 
wire to junction box on fireplace insert 
  after finishing wall. 
3) Remove the outer jacket and strip the 
  individual conductors ½” from end.
4) Loosen the screw securing the junction
  box cover and remove the cover.
5) Place unit in position in the framed  
opening, level with shims if necessary 
  and attach unit to frame using mounting 
flanges provided ( see Section 3).
6) Wire a dedicated, properly fused circuit with 
a 15 amp rating for the appropriate voltage 
(120, 208/240). (See table above) 
7) Install wall thermostat as outlined on
  page 10 section E
8) Place all connections inside the junction 
box. Secure the junction box cover on the 
unit. 
  When installing a cable clamp make sure it 
grips only the jacket of the service cable 
  and thermostat wire.
STEP - BY - STEP INSTALLATION OVERVIEW
(please read all instructions before installation)