ZyXEL Communications 1111 ユーザーズマニュアル

ページ / 22
Chapter 4 SHD2110/3110 Programming
Z-Wave Series Programming Guide
20
Accumulated power consumption (KW/h) = (Meter Value 2*65536) + (Meter Value 3*256) + 
(Meter Value 4) = 70.1 (KW/h)
4.2.4.3  Clearing Accumulated Power Consumption
4.2.5  Command Classes
The SHD2110/3110 supports the following Command Classes: 
• COMMAND_CLASS_SWITCH_BINARY
• COMMAND_CLASS_BASIC
• COMMAND_CLASS_MANUFACTURER_SPECIFIC
• COMMAND_CLASS_VERSION
• COMMAND_CLASS_SWITCH_ALL
• COMMAND_CLASS_ASSOCIATION_V2
• COMMAND_CLASS_METER_V2
• COMMAND_CLASS_ALARM
• COMMAND_CLASS_CONFIGURATION
Meter Report Command
[Command Class Meter,Meter Report,Rate
Type+Meter Type, Precision+Scale+ Size, Meter Value 1, Meter Value 2]
Meter Reset Command 
[Command Class Meter, Meter Reset]