Installation 
FX 20VL Controls
 
 
 
The heater is fitted with a thermostat with  
Before undertaking installation work, ensure the electricity supply is 
disconnected from any relevant fixed wiring. Supply cable is not supplied 
with this appliance and it should therefore be installed by a competent 
electrician in accordance with the IEE wiring regulations. 
an Integrated ON/OFF switch, a cut-out,  
and a thermal fuse link. 
The heater has an external adjustable  
thermostat which can be adjusted by user  
 
The supply circuit must be adequate for the input of the appliance and 
must be protected with a 13A fuse. 
(i.e. by turning the knob to the side of the  
heater), see Fig 4 for controls details.  
A suitable termination to the fixed wiring of the premises must be provided 
adjacent to the final position of the appliance through a double pole switch 
having a contact separation of at least 3mm in all poles. 
Temp. range 7°C - 32°C 
 
 
 
 
 
 
 
 
 
Fig. 3 
 
 
 
 
Installation Procedure 
 
 
 
It is essential to observe minimum wall mounting clearances, as per Fig. 1 
overleaf. 
 
 
The appliance should be fitted horizontally, with the cable entry at the top 
and grille at the bottom. It must be mounted not less than 600mm above 
the floor with a clearance of at least 600mm to any shelf or projecting 
surface below the heater and not less than 300mm below the ceiling or 
other projecting surface. It must also be not less than 250mm from an 
adjacent projecting surface. For most effective heating performance, the 
heater should be mounted at the minimum height :- 
 
 
 
 
 
i.e.- 600mm  above the floor. 
 
 
 
Care must be taken to ensure that when in use, the air stream is not 
obstructed by a high shelf or cabinet. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Cleaning and User Maintenance 
 
 
 
 
 
 
 
 
 
 
 
Fig. 2 
WARNING 
 
 
BEFORE UNDERTAKING CLEANING OR MAINTENANCE WORK ON 
THE APPLIANCE IMMEDIATELY DISCONNECT THE ELECTRICITY 
SUPPLY BY SWITCHING OFF AT THE ADJACENT DOUBLE POLE 
SWITCH. 
The appliance is secured to the wall with three screws, two through 
keyhole slots and one through a centrally positioned lower hole to hold the 
appliance firmly in position (see Fig 2). 
 
1.  Remove the top cover from the appliance by removing the two 
screws securing the top cover and hinging it back. 
 
The outside can be cleaned by wiping it over with a soft damp cloth and 
then dried. Do not use abrasive cleaning powders or furniture polish as 
this can damage the surface finish. 
2.  Mark the position of the keyhole slots on the wall and drill and plug 
for the two suitable screws. 
3.  Partially insert the two screws, then hang the appliance on these 
screws and mark the position of the lower centrally positioned screw. 
 
After Sales Service 
4. 
Remove the appliance and drill and plug for the third screw. 
 
Your Dimplex downflow fan heater is guaranteed for one year from the 
date of purchase. We undertake to repair or exchange free of charge 
within this period, any part found to be defective due to a manufacturing 
fault. 
5. 
Remount the appliance on the wall, ensure that it is horizontal and fix 
in position by tightening all three screws. 
6.  Feed the supply cord or wires through the inlet at the top rear
 
of the 
appliance leaving sufficient free length to connect to the terminal 
block.