Procom ML250HPA ユーザーズマニュアル

ページ / 25
15
TROUBLESHOOTING
Continued
OBSERVED  PROBLEM
Burner(s)does  not   light  aft er
ODS/pilot   is  lit.
Delayed   ignition  of  burner(s).
Burner  backfiring  during  combustion.
Burner  Plaque(s)  does  not  glow.
Slight   smoke   or   odor   during
initial   operation.
Heater   produces   a  clicking/ticking
noise  just  after  burner  is  lit  or
shut  off.
White  powder residue forming  within
burner    box    or    on    adjacent
walls  or   furniture.
POSSIBLE CAUSE
1.    Burner orifice is clogged.
2.   Burner  orifice  diameter  is too small.
3.    Inlet  gas  pressure  is  too  low.
1.   Manifold  pressure  is  too  low.
2.   Burner orifice is clogged.
1.  Burner   orifice   is  clogged   or
      damaged.
2.   Burner  is  damaged.
3.   Gas  regulator  is defective.
1.   Plaque damaged.
2.   Control  knob  set  between  locked
       positions.
3.   Inlet gas  pressure  is  too  low.
1.   Residues  from  manufacturing
       processes.
1.   Metal  expanding  while  heating  or
      contracting  while  cooling.
1.   When      heated,    vapors     from
        furniture    polish,    wax,    carpet
      cleaners,     etc.   turn   into   white
       powder  residue.
REMEDY
1.   Clean burner  orifice (see Cleaning
        and   Maintenance,  Page  13)    or
      replace burner orifice.
2.   Replace burner orifice.
3.   Contact  local  Propane/LP gas company.
1.   Contact   local  Propane/LP gas company.
2.  Clean  burner (see Cleaning  and
      Maintenance
,  Page 13)  or replace
      burner  orifice.
1.   Clean  burner  orifice  (see  Cleaning
    and   Maintenance,   Page  13) or
      replace burner orifice(s).
2.  Contact Dealer or PRO-COM.
3.   Replace  gas  regulator.
1.   Replace  burner.
2.   Turn  control  knob  until  it  locks  at
      desired  setting.
3.  Contact    local   propane/LP   gas
      company.
1.   Problem  will stop after a few hours
      of operation.
1.   This  is  common  with  most  heaters.
       If      noise    is     excessive,   contact
      qualified  ser vice  person.
1.  Turn   heater   off   when   using
      furniture    polish,    wax,   carpet