Allied International Home Security System ユーザーズマニュアル

ページ / 63
Safety instructions
Hardware Installation Guide V2.0.0
15
PIKE/STINGRAY GOF connectors
PIKE/STINGRAY voltages
The inputs can be connected directly to +5 V. If a higher voltage is used, an 
external resistor must be placed in series. Use at +12 V a 820 
Ω resistor and 
at +24 V a 2.2 k
Ω resistor.
GUPPY voltages
Caution
a
Special warning for all PIKE/STINGRAY models with GOF 
connectors:
GOF connectors are very sensitive. Any dust or dirt may 
cause damage.
Always keep the GOF connector and optical fiber plug 
clean.
If GOF connection is not in use, keep GOF dust cover on 
the GOF connector.
Reduce mating cycles to a minimum to prevent abra-
sion.
Please note that optical fiber cables have a very limited 
deflection curve radius.
Caution
a
PIKE/STINGRAY
Voltages above +45 V may damage the optical coupler.
Caution
a
GUPPY
If using voltages higher than + 5 V the input of the cam-
era will be damaged.
To avoid damage of the input, use an external resistor in 
series (outside of the camera).
Recommendations for resistors by voltages higher than + 5 V:
Use at +12 V a 18 k
Ω resistor.
Use at +24 V a 47 k
Ω resistor.
For details see