Outputs GUPPY
The standard Guppy cameras have 3 inverting outputs.
Outputs
Operating conditions
Output voltage
0 ... 5.5 V
Output current
Max. 
± 20 mA
 Table 19: Output parameters (GUPPY)
Note
L
For information on output features (IntEna, Fval, Busy) and 
configuration via registers see Technical Manuals.
Guppy board level cameras have physically 4 I/Os and logi-
cally 4 inputs and 4 outputs. For information on I/Os and 
PWM of board level cameras see Technical Manuals.