JAI AD-081GE ユーザーズマニュアル

ページ / 82
AD-081GE 
25 
Minimum PC requirements are as follows in order to fulfill the above conditions: 
  Intel Core 2 Duo , 2.4 GHz or better   
  At least 2 GB memory 
  Video Card with PCI Express Bus x 16, VRAM better than DDR2 with 256 MB or more, and 
display capability of 2560 x 1600 
  Windows XP, SP2 (32bit) 
  Functions such as screen saver and power save should not be used. Unnecessary applications 
such as Word, Excel or others should not be used. 
Note: Pentium 4 type PC is not recommended due to dependency on chip set bus performance. 
10.2.2      Video data rate (network bandwidth) 
The video bit rate for the AD-081GE in Continuous mode is: 
Model 
Pixel Type 
Packet data volume   
(assumes the packet size is 1428) 
AD-081GE   
 
MONO8 
196 Mbit/s 
MONO10_PACKED 
MONO12_PACKED 
294 Mbit/s   
 
MONO10 
MONO12 
392 Mbit/s   
  In the case of using Jumbo Frames (16K), the packet data will be improved by 2 %. 
  For AD-081GE, the jumbo frame size can be a maximum 16020 Bytes (factory setting is 1476 
Bytes). The NIC must also be set to support Jumbo Frames (refer to section 10.2.4). 
  Based on the Pixel Type, the packet size may be automatically adjusted inside the camera to   
its most suitable value .   
To ensure the integrity of packets transmitted from the camera, it is recommended to follow 
these simple guidelines: 
1.  Whenever possible use a peer-to-peer network. 
2.  When connecting several cameras going through a network switch, make sure it is 
capable of handling jumbo packets and that it has sufficient memory capacity. 
3.  Configure inter-packet delay to avoid congestion in network switches. 
4.  Disable screen saver and power save functions on computers. 
5.  Use high performance computers with multi-CPU, hyper-thread and 64-bit CPU, etc. 
6.  Only use Gigabit Ethernet equipment and components together with the camera.   
7.  Use at least Cat5e and preferably Cat6 Ethernet cables. 
8.  Whenever possible, limit the camera output to 8-bit. 
    Note for setting packet size     
The packet size is set to 1428 as the factory default. Packet size can be modified in the GigE 
Vision Transport Layer Control section of the camera control tool (see below). For AD-081GE, 
users may enter any value for the packet size and the value will be internally adjusted to an 
appropriate, legal value that complies with the GenICam standard. Thus, the actual packet 
size may be different than the value entered by the user.   
Caution: do not set the packet size larger than the maximum setting available in the NIC or 
switch to which the camera is connected (see section 10.2.4). Doing so will cause output to 
be blocked.