Golden Technologies GA 541 ユーザーズマニュアル

ページ / 35
Avenger Owner’s Manual   
DIAGNOSTICS SYSTEM
 
 
TruCharge Battery Display Diagnostics 
 
NOTE: When the display is down to two (2) bars, the batteries must be charged 
before driving your Avenger.™
 
 
Fault 
Type 
Description 
Bars  
Self Help Guide 
Show if reaching low 
voltage 
1 bar 
The battery needs charging or there is a 
bad connection to the battery. Check all 
connections between the controller and 
the battery. If the connections are good, 
try charging the battery.  
Motor disconnected 
2 bars 
There is a bad connection to the motor. 
Check all of the connections between 
the motor and the controller.  
Motor wiring fault 
3 bars 
The motor has a short circuit to a 
battery connection. Contact your service 
agent. 
Parking brake off 
4 bars 
The freewheel switch or manual brake 
disengagement mechanism is operated. 
Check the position of the switch or 
lever. 
Not used 
5 bars 
Not used. 
Inhibit active 
6 bars 
The controller is being inhibited from 
driving; this may be caused because the 
battery charge is still connected or the 
seat is not in the proper driving position. 
7 Throttle 
potentiometer 
fault 
7 bars 
A throttle fault is indicated. Make sure 
the throttle is in the rest position before 
switching on the scooter. 
Possible controller fault  8 bars 
A controller fault has been indicated. 
Contact your service agent. 
Solenoid brake fault 
9 bars 
There is a bad connection to the parking 
brake. Check all connections between 
the parking brake and the controller. 
10 
High battery voltage 
10 bars  An excessive voltage has been applied 
to the controller. This is usually caused 
by a poor battery connection. Check all 
connections between the battery and 
controller.  
 
WARNING:  DO NOT OPERATE THE SCOOTER IF THE BATTERY IS NEARLY 
DISCHARGED.  FAILURE TO COMPLY WITH THIS CONDITION MAY LEAVE THE USER 
STRANDED IN AN UNSAFE POSITION.