Mitsubishi Electronics AJ61QBT11 ユーザーズマニュアル

ページ / 294
 
 
 
12 - 11 
MELSEC-QnA 
12   COMMUNICATION IN THE COMPOUND SYSTEM 
 
K1
SM400
FROM H0004 H00E2
K2
K4M20
RET
TO H0004
H01E5
K1
D200
P20
Remote 
READY (RX1B) 
Communication  
program with  
AJ65BT-64AD 
M44
MOV
D200
H0202
Average processing  
specification 
(CH2 average time) 
  (Initial data processing request flag: RX18) 
RST
M144
RST
M145
M44
M45  (Initial data setting complete flag: RX19) 
M47
CH1 digital output value 
TO H0004 H0162
K4M120 K2
SM400
Write AJ65BT-64AD remote  
output (RY)
MOV
D202
K60
MOV
D205
H0001
Data type (-2048 to 2047) 
MOV
D206
H0003
A/D conversion enable/disable  
specification 
(CH1, CH2 conversion
 permission) 
TO H0004
H01E6
K1
D202
TO H0004
H01E9
K2
D205
SET
M144
Initial data processing complete 
                                       (RY18) 
SET
M145
Initial data setting request 
                                       (RY19) 
M20 (CH1 A/D conversion complete flag: RX0) 
FROM H0004 H02E4
K1
D210
CH2 digital output value 
M21
FROM H0004 H02E5
K1
D211
Read the digital  
value 
M46
Error code 
  (Error status flag: RX1A) 
FROM H0004 H02E8 D212
Error reset request (RY1A) 
X60
Read the error 
code 
M146
Initial settings
Read AJ65BT-64AD remote 
input (RX) 
CH2 Average time, 
number of times (60ms) 
(CH2 A/D conversion complete flag: RX1) 
Data format specification
(-2048 to 2047)