5.3 Serial Communication
5.3.3 INPUT instruction
5-73
G_INPUT
5
MODULE DEDICA
TED 
INSTRU
CTI
O
N
G_I
N
PUT
5.3.3  
INPUT instruction
G_INPUT
*1: Local devices and file registers per program cannot be used as setting data.
Function
This instruction receives data in the message format specified by the user using the 
nonprocedural protocol.
G_INPUT
 indicates any of the following 
instructions.
G_INPUT
Input argument
EN:
Executing condition
:Bit
Un*:
Start I/O number of the module
(00 to FE: Higher two digits when expressing the I/O number in 
three digits)
:ANY16
s:
Variable that stores control data
:Array of ANY16 [0..3]
Output argument
ENO:
Execution result
:Bit
d1:
Start number of the device that stores receive data
:ANY16
d2:
Variable that turns ON upon completion of the instruction
d2[1] also turns ON at the time of error completion.
:Array of bit [0..1]
Setting
data 
*1
Internal device
R, ZR
J
\
U
\G
Zn
Constant Others
Bit
Word
Bit
Word
Serial
Structured ladder/FBD
ST
G_INPUT
EN
ENO
d1
Un*
s
d2
G_INPUT
(EN, Un*, s, d1, d2);
ENO:=
s
d1
d2