5.4 Network Dedicated Instruction
5.4.29 BUFSND instruction
5-233
ZP_BUFSND
5
MODULE DEDICA
TED 
INSTRU
CTI
O
N
ZP
_
B
U
F
SN
D
5.4.29  
BUFSND instruction
ZP_BUFSND
*1: Local devices and file registers per program cannot be used as setting data.
Function
This instruction sends data to external device in fixed buffer communication.
ZP_BUFSND
Executing condition
:
 indicates the following instruction.
ZP_BUFSND
Input argument
EN:
Executing condition
:Bit
Un*:
Start I/O number of the module
(00 to FE: Higher two digits when expressing the I/O number in 
three digits)
:String
s1:
Connection number (1 to 16)
:ANY16
s2:
Variable that stores control data
:Array of ANY16 [0..1]
s3:
Start number of the device that stores write data
:ANY16
Output argument
ENO:
Execution result
:Bit
d:
Variable that turns ON upon completion of the instruction
d[1] also turns ON at the time of error completion.
:Array of bit [0..1]
Setting
data 
*1
Internal device
R, ZR
J
\
U
\G
Zn
Constant
K, H
Others
Bit
Word
Bit
Word
Ether
Structured ladder/FBD
EN
ENO
Un*
d
s1
s2
s3
ZP_BUFSND
ST
ZP_BUFSND
(EN, Un*, s1, s2, s3, d);
ENO:=
s1
s2
s3
d