National Instruments PXI-1006 User Manual ユーザーズマニュアル

ページ / 46
Appendix A
Specifications
© National Instruments Corporation
A-3
Slot airflow direction.............................. P1 to P2, bottom of module to top
of module
Module/power supply cooling intake..... Three rear fans
Module cooling exhaust ......................... Along both sides and top of
chassis
Power supply cooling system................. Forced air circulation via
integrated fan
Power supply cooling exhaust................ Along upper left side
Power supply/fan unit ............................ Replacement in under 5 minutes
Electromagnetic Compatibility
EMC/EMI............................................... CE, C-Tick and FCC Part 15
(Class A) compliant
Electrical emissions................................ EN 55011 Class A @ 10 m.
FCC Part 15A above 1 GHz
Electrical immunity................................ Evaluated to EN 61326:1998,
Table 1
Note
This device should be operated only with shielded cabling for full EMC and
EMI compliance. See the Declaration of Conformity for this product for any additional
regulatory compliance information.
Safety
Designed in accordance with IEC 61010-1, EN 61010-1, UL 3111-1, and
CAN/CSA C22.2 No. 1010.1 for electrical measuring and test equipment
Installation Category II
Pollution Degree 2
Environmental
Operating temperature............................ 0 to 50 °C
Storage temperature ............................... –20 to 70 °C
Operating relative humidity ................... Maximum 80% for temperatures
up to 31 °C, decreasing linearly
to 50% at 40 °C