Figure 3-2 Sample of Alarm Input (Normal Close Type) 
 
Alarm Output Port 
•  Three ways to relay alarm output (NO contact). External power supply 
is needed for external alarm device. 
•  To avoid overloading, please read the following relay parameters sheet 
carefully. 
 
Relay Specification: 
Model 
JRC-27F 
Material of the touch  
Silver  
Rating 
(Resistance 
Load)  
Rated switch capacity  
30VDC 2A, 125VAC 1A  
Maximum switch power  
125VA 160W  
Maximum switch voltage  
250VAC, 220VDC  
Maximum switch currency  
1A  
Insulation  
Between touches with same polarity  
1000VAC 1minute