4 DIAGNOSTICS 
Diagnostics are displayed on the on-screen display (OSD) and front-panel display. 
They confirm proper installation, including:  
•  Checking error states and signal integrity 
•  Identifying the cable terminal on the network 
•  Verify communications with the headend 
For the diagnostics described in this section: 
•  All indicators are in decimal notation, unless otherwise noted. 
•  All signal-level and quality indicators use a 1% to 100% scale, unless otherwise 
noted. 
•  All sample displays are illustrative; actual data may differ from the examples. 
Using the Diagnostics 
To use the diagnostics: 
1.  Ensure that the DCH6416 is installed with the Thin Client software and that it is 
connected to an AC outlet.  
2. Press 
POWER
 and immediately press 
SELECT
 to enable diagnostic mode. The 
Diagnostics main menu is displayed on the OSD and “d01” is displayed on the 
front-panel display: 
Figure 4- 1 Example of the Front panel display for the main menu 
 
You can use the following keys to navigate the diagnostics menus: 
• Press 
channel 
▲, channel ▼, cursor ▲, or cursor ▼ to select d01 through E. 
• Press 
cursor 
◄, cursor ►, select or enter to execute the selected diagnostic. 
•  Select E from the main menu or press power to exit. 
General Status 
This diagnostic displays system status information on the OSD and front panel. The 
information is updated each time the diagnostic is displayed.