Planet Technology DVR-470 ユーザーズマニュアル

ページ / 99
                                                                                                                                                                                           
Page 60 
 
5.13  External Alarm Input and Relay Output 
For DVR-470, there are 4 external alarm input and 2 relay output. For DVR-1670, there are 
16 external alarm input and 4 relay output. In “Alarms” menu, you can setup for each 
external alarm input. In main menu, move “Active Frame” to “Alarms” icon and press
ENTER】key to enter into alarms menu: 
 
 
External alarm input setup 
Step 1Select one alarm input   
Use【↑】【↓】keys to select one alarm input. 
 
Step 2Alarm type   
This is sensor type. You can select “Normal Open” or “Normal Close” according to the 
sensor type. 
 
Step 3Enter into “Alarm in Handling” sub menu   
In the “Alarms” menu, there are two options for “Alarm Handling” item. One is “Ignore”, 
and the other is “Handle”. If you select “Handle” option, you can active “Policy” and “PTZ 
Linkage” buttons on right side. Move “Active Frame” to “Policy” button and press【ENTER】
key, you will enter into “Alarm in Handling” sub menu: