Planet Technology DVR-470 ユーザーズマニュアル

ページ / 99
                                                                                                                                                                                           
Page 98 
 
Appendix E  Troubleshooting 
Failure Possible 
reasons 
After plugging in power, turning on the power switch, 
“POWER” light in front Panel does not turn on, and fan 
does not work.   
1)  Power cable is broken. 
2)  Power supply is broken. 
 
After plugging in power, turning on the power switch, 
“POWER” light in front panel turn to green while fan does 
not work.   
1)  Front panel cable is broken. 
2)  Fan is broken. 
After plugging in power, turning on switch, “POWER” 
light turn to green, the indicator lights in the panel turn on 
at the same time, but fan does not work. 
The ATX plug in main board is 
not well plugged in. 
DVR continuously reboots after start up, and makes a 
sound like “di” every 10 seconds. 
1)  Upgrade the wrong firmware
2)  Compression board has 
problems. 
3)  Main board has problems. 
There are no images in the monitor connected with VOUT 
after DVR is started. 
1)  The cable connected with the 
monitor is broken. 
2)  Real board of DVR has 
problems. 
3)  Main board of DVR has 
problems. 
Cannot find the hard disk in reboot process. 
1)  Hard disk cable is broken. 
2)  The power cable of hard disk 
is not connected. 
3)  Hard disk is broken.   
No reponse in HyperTerminal interface.   
1)  Baud rate is not matched. 
2)  RS-232 cable is broken. 
3)  Serial port of PC is broken. 
4)  RS-232 port of DVR is 
broken. 
DVR can not control PTZ through RS-485 port. 
1)  RS-485 cable is not 
connected correctly or 
broken. 
2)  PTZ parameters error. 
3)  RS-485 port of DVR is 
broken. 
Client software can not view DVR live image.   
1)  Network is error. 
2)  Connect wrong DVR (wrong 
IP, port number, username or 
password, ect).