Speco Technologies D16RS ユーザーズマニュアル

ページ / 94
29 
Note:  Connect  PTZ  cameras  that  support  RS-485  directly  to  the  RS-485  port.  If  the  camera  is  controlled 
through an RS-232C interface, use an RS-232C to RS-485 to RS-232C signal converter. 
 
Use the PTZ setup screen to select the following options for the camera PTZ controller: 
CHANNEL: Channel connected to a PTZ device 
CAMERA: Protocol Type 
SPEED: 19200, 14400, 9600, 4800, 2400 (Baud rate) 
ID: 0-63 
 
Controller (Keyboard Controller): If a PTZ controller is used, select a controller protocol from Controller 
menu. Set SPEED (Baud Rate) and ID number. 
 
4-4-3.  Spot Out 
 
Figure 4.4.6. SPOT-OUT Setup Screen 
 
Table 4.4.4. Menu Item in SPOT-OUT Setup Screen 
Item 
Description 
SPOT OUT 
Only 1 Spot Out is available to use.   
To  use  the  Spot  out  function  on  D4RS,  Video  Resolution  has  to  be 
setup  as  1280x1024  (Video  Resolution  Output  can  be  setup  on 
DISPLAY MENU.)   
SPOT TYPE 
SPOT 1 supports only FULL type. (1 channel only) 
SPOT ON EVENT 
Enable/disable channel change if an event occurs on a channel.   
SPOT EVENT   
DWELL TIME 
Set the dwell time for the display of the event activated channel. 
(1-10sec) 
SEQUENCE 
Enable/disable sequential display of spot channel in full screen. 
If  select  ON,  the  selected  channel  will  be  displayed  on  the  monitor 
periodically. 
SEQUENCE 
DWELL TIME 
Set the dwell time for the spot channel display.(1-10sec) 
SPOT CHANNEL 
Select  a  channel  for  spot  monitoring  using  the  mouse  or  the  control 
button on the remote control and press OK button.