Speco Technologies DVR-X1 ユーザーズマニュアル

ページ / 26
                                             
       
DVR-X1 User Manual 
  
(Sensor triggers the alarm and starts recording after 0.2 second) 
2: 0.5 Sec. 
(Sensor triggers the alarm and starts recording after 0.5 second) 
3: 1 Sec. 
(Sensor triggers the alarm and starts recording after 1 second) 
4: 2 Sec. 
(Sensor triggers the alarm and starts recording after 2 second) 
        5: 5 Sec. 
 
(Sensor triggers the alarm and starts recording after 5 second) 
 Sensor Type
 
NC → Normal-close sensor ( TTL level input 
Set to NC, to trigger the recording when the sensor has 
been opened.
 
NO → Normal-open sensor ( TTL level input 
Set to NO, to trigger the recording when the sensor has 
been closed. 
                   
 
Post-alarm Time
:The extra recording time, straight after when the 
sensor recording event ended (Time setting range from 0~99 Sec). 
 
19