3. Installation
 
 
Rear panel 
Power Supply
  12V DC,4A. 
VIDEO IN
  Image signal input, connected to the video source. 
VIDEO OUT
:“VIDEO OUT” is connected to monitor ”VIDEO IN”. 
VCR OUT
:“VCR OUT” can be connected to the ”VIDEO IN” of a VCR. 
AUDIO IN
:For a MIC connection. 
AUDIO OUT
:Line Level for live and Audio playback. 
SENSOR/ALARM
  There is a DB9 connector on the right side of the rear 
panel, which is connected to any external sensors and 
alarm output (Relay). 
FAN
:To radiate hot air 
 
 
The DVR-X1 automatically detects NTSC/PAL, please connect the 
video source before turning on the DVR. 
 
 
 
DB9 PIN CONFIGURATION: 
 
3 GND 
Ground 
Sensor Trigger Input – 1 
External sensor input 
7      Relay Out – COM 
Replay output COM terminal 
8      Relay Out – N.O. 
Replay output normally open   
9      Relay Out – N.C. 
    Replay output normally closed 
 