GSI Outdoors PNEG-1521 ユーザーズマニュアル

ページ / 64
INSTALLATION
14
PNEG-1521     Commercial Direct Gear Drive Bin Sweep Auger
A. Cut openings in the bin floor for the Intermediate wells. (See figure below.) The number of wells
depends on bin size. The distance between Intermediate wells and the Centerwell should be equal.
3. INTERMEDIATE WELL INSTALLATION
36'
3
17' 10-7/8"
36.363''
53.75''
250.888''
36.013''
42'
4
20' 10-11/16"
32.613''
50.00''
286.638''
35.950''
48'
4
23' 10-1/2"
39.863''
57.25''
322.388''
35.888''
54'
4
26' 10-1/4"
47.113''
64.50''
358.388''
36.138''
60'
5
29' 10-1/8"
42.363''
59.75''
394.138''
36.013''
72'
6
35' 9-3/4"
44.113''
61.50''
465.638''
35.888''
75'
6
37' 3-5/8"
46.613''
64.00''
483.638''
36.013''
78'
6
38' 9-9/16"
49.113''
66.50''
501.638''
36.075''
DISTANCE 
FROM CENTER 
OF BIN TO 
WALL (A)
NUMBER OF 
INTERMEDIATE 
WELLS
BIN SIZE
DISTANCE 
FROM BIN 
WALL TO 
ANGLE RING
DISTANCE 
FROM CENTER 
OF BIN TO 
ANGLE RING (D)
DISTANCE 
BETWEEN 
WELLS (C)
DISTANCE BETWEEN 
CENTERWELL AND 
FIRST INTERMEDIATE 
WELL (B)
FIG. 3-A INT-WELLS
INTERMEDIATE WELL LOCATION AND CUT-OUT
FIG. 3-B SIDE VIEW DISTANCE