Lucent Technologies 555-661-150 ユーザーズマニュアル

ページ / 360
MERLIN LEGEND Communications System Release 6.1
Network Reference  
555-661-150  
Issue 1
August 1998
Call-Handling Scenarios 
Page 2-77
Network Configuration Scenarios 
2
To reach System G, the routes for intersystem voice calls direct them from 
Systems F and H via the hub, System E, where they are then sent to 
System G over tandem tie facilities. FRLs for routes to System G are 
slightly higher to avoid excessive call volume over the analog tandem tie 
trunks.
NOTE:
In Release 6.1 and later, it is important to note that coverage to the 
centralized VMS/AA from remote private network systems must be 
limited to only one span. This means that a call may only pass 
through one tandem trunk to the centralized VMS/AA on the hub 
system.
Calls between extensions on Systems E, F, and H do display caller 
information, according to display preference settings, at the destination 
MLX display extensions.
 shows how the system managers set up their local 
systems for use of local PSTN facilities and non-local PSTN facilities. Remote 
Access codes are not shown but are set up to be unique and unambiguous across 
the private network. As you review the table, keep the following points in mind:
To avoid confusion and for future planning purposes, tandem trunks and 
pools of tandem trunks are also numbered uniquely and unambiguously. 
System H users do not make Interexchange calls. The system’s loop-start 
line is assigned to the main pool, Pool 70. 
CAUTION:
!
Unless networked systems are co-located, each system should have 
at least one loop-start line connected to the PSTN. The line is 
required to allow connection of a power-failure telephone to the 
Power-Failure Transfer (PFT) jack on a module as a power outage 
backup and for correct routing of emergency and other N11 (911, 411, 
etc.) calls. To ensure that the correct services are reached, if the 
loop-start line is used for emergency or other N11 calls, it should be 
assigned to the main pool. In this case, inter-exchange (IXC) calls 
determine the number of loop-starts required. Refer to Feature 
Reference
 guide for details on the PFT feature.
The hub system, System E, can support only two tandem PRI trunks to 
connect to Systems H and F, because it also requires a number of outside 
facilities. It is using the maximum system capacity of 80 lines/trunks. Its 
100D module is in the last circuit module position in the control unit and 
uses only 20 lines of its 23-line capacity. There is no emergency loop-start 
line connected to the system, therefore other power failure arrangements 
should be made. Compare the limitations with those of Scenario 3, shown 
in 
Figure 2–4 on page 2–58
.