 Setting up Your System
3 - 15
the phone needs to read, such as the application executable and the standard 
configuration files, should be made read-only through file server file 
permissions.
Deploying Phones From the Boot Server
You can successfully deploy SoundPoint IP and SoundStation IP phones from 
one or more boot servers.
Multiple boot servers can be configured by having the boot server DNS name 
map to multiple IP addresses. The default number of boot servers is one and 
the maximum number is eight. HTTPS, HTTP, and FTP are supported for 
redundant boot servers.
To deploy phones from the boot server:
1.
(Optional) Create per-phone configuration files by performing the 
following steps:
a
Obtain a list of phone Ethernet addresses (barcoded label on 
underside of phone and on the outside of the box).
b
Create per-phone phone[MACaddress].cfg file by using the 
phone1.cfg file from the distribution as templates.
For more information on the phone1.cfg file, refer to 
 on page 
c
Edit contents of phone[MACaddress].cfg if desired. 
For example, edit the  parameters.
Note
For more information on encrypting configuration files, refer to 
 on page 
.
Note
This step may be omitted if per-phone configuration is not needed.
Note
Throughout this guide, the terms Ethernet address and MAC address are used 
interchangeable.