Patton electronic SmartNode 4110 Series ユーザーズマニュアル

ページ / 664
PRI port configuration task list
195
SmartWare Software Configuration Guide 
16 • PRI port configuration
Configuring PRI line-build-out (E1T1 in T1 mode only)
The line build out configuration is used in long haul applications to prevent cross talk in the far end device.
Mode: port e1t1 <slot> <port>
Configuring PRI used-connector (E1T1 in E1 mode only)
If the E1T1 WAN-Card provides several line interface connector types this command specifies which one is 
currently in use. Sure, the signal is always on all connectors available but dependent on the wiring technology 
the internal impedance matching must be adapted (RJ45 = 120 Ohm; BNC = 75 Ohm). 
Mode: port e1t1 <slot> <port>
Configuring PRI application mode (E1T1 only)
The PRI port can be configured to work in either short-haul or in long-haul mode. Short-haul is the default 
application and should be used for transmission distances up to 180m/600ft. For transmission distances up to 
1800m/6000ft, select the long-haul application.
Mode: port e1t1 <slot> <port>
Step
Command
Purpose
1
[name] (prt-e1t1)[slot/port]# line-build-
out {0 | -7.5 | -15 | -22.5}
Specifies the pulse attenuation in dB on the line inter-
face.
Restriction: Only available for e1t1 ports in T1 
mode.
Default for t1: 0 dB
Step
Command
Purpose
1
[name] (prt-e1t1)[slot/port]# used-con-
nector {bnc | rj45}
Specifies the currently used connector.
Restriction: Only available for e1t1 ports in E1 
mode.
Default for e1: rj45
Step
Command
Purpose
1
[name] (prt-e1t1)[slot/port]#application 
{long-haul | short-haul}
Specifies the e1/t1 application mode
Restriction: Only available for e1t1 ports
Default: short-haul