17 • BRI port configuration
BRI Debugging
For the investigation of possible problems in link establishment, data transmission or synchronization, there 
exists a debug command with the options ‘event’ and ‘error’. The command has a hierarchical characteristic 
and can be applied to all ports on the whole device, or to all ports of slot or just to one specific port. In addi-
tion, the ‘show port’ command can be used to printout information about the current configuration and about 
received and transmitted frames.
Mode: Operator execution
Mode: Operator execution
Step
Command
Purpose
1
[name]#[no] debug bri
[ ( [<slot> | [<port>] ] ) | [ [event] | 
[error] ] ]
Enables/Disables the BRI event/error monitor for the 
device a slot or a port.
Default: no debug bri
Examples:
1)[no] debug bri
Enables/Disables the event and the error monitor for 
all bri ports of the device.
2)[no] debug bri event
Enables/Disables the event monitor for all bri ports 
of the device.
3)[no] debug bri error
Enables/Disables the error monitor for all bri ports 
of the device.
4)[no] debug bri 3
Enables/Disables the event and error monitor for all 
bri ports on slot 3.
5)[no] debug bri 1 event
Enables/Disables the event monitor for all bri ports 
on slot 1.
6)[no] debug bri 2 error
Enables/Disables the error monitor for all bri ports 
on slot 2.
7)[no] debug bri 0 0
Enables/Disables the event and error monitor for the 
bri port 0 on slot 0.
8)[no] debug bri 1 0 event
Enables/Disables the event monitor for the bri port 0 
on slot 1.
9)[no] debug bri 2 0 error
Enables/Disables the error monitor for the bri port 0 
on slot 2.
Step
Command
Purpose
1
[name]#show port bri
[ [<slot> <port>] | [detail <level>] ]
Prints information about the specified port with a 
given detail level.