ISDN configuration task list
221
SmartWare Software Configuration Guide 
19 • ISDN configuration
2
node(q931)[slot/port]#signalling-rule 
etsi
or
node(q931)[slot/port]#signalling-rule 
pss1old
or
node(q931)[slot/port]#no signalling-rule
Specify channel numbering (Default: etsi)
Some older Q-SIG variants make use of a 
channel numbering scheme that differs from 
the standard ETSI method. In most cases the 
ETSI numbering applies. Unless the connected 
ISDN devices and configured protocols 
require a different scheme, make sure the 
numbering is set to ETSI.
3
node(q931)[slot/port]#uni-side net 
or
node(q931)[slot/port]#uni-side user
Specify the UNI side of the interface.
If not defined on layer2 (q921 mode) this set-
ting also specifies the UNI side setting for 
layer2.
The layer 2 settings also apply to Q.SIG 
(PSS1) interfaces.
Make sure that the device connected to a 
SmartNode ISDN port is operating the oppo-
site side of the configured uni-side.
4
node(q931)[slot/port]#max-calls number-
of-calls
or
node(q931)[slot/port]#no max-calls
Limits the total number of concurrent calls 
on the port.
The no form of the command restores the 
default settings.
Note
if the channel-range and 
max-calls command are 
used simultaneously, the 
lower number of chan-
nels is the limiting 
parameter.
5
node(prt-pstn)[slot/port]#channel-range 
min max
or
node
(prt-pstn)[slot/port]#no channel-
range
Specify B-channel range to be used on a PRI 
port (Default: E1: 0-31, T1: 0-23)
Limits the time-slots to be used for calls to the 
range between min and max. This is in some 
cases required for interoperability with ISDN 
services that impose the same limitations.
Call slots outside the defined range are 
rejected (busy line). If no range is defined 
(Default) all 30 (T1: 23) time-slots are avail-
able for use.
The no form of the command restores the 
default settings.
Step
Command
Purpose