Patton electronic SmartNode 4110 Series ユーザーズマニュアル
Activating CS context configuration
351
SmartWare Software Configuration Guide
31 • CS context overview
02:14:30 CR > Updating tables in 3 seconds...
02:14:33 CR > [switch] Reloading tables now
02:14:33 CR > [switch] Flushing all tables
02:14:33 CR > [switch] Loading table 'TAB-ISDN-SERVICE'
02:14:33 CR > [switch] Loading table 'TAB-DEST-A'
02:14:33 CR > [switch] Loading table 'CAC-APPLE'
02:14:33 CR > [switch] Loading table 'CAC-ORANGE'
02:14:33 CR > [switch] Loading table 'CLI-MELON'
02:14:33 CR > [switch] Loading table 'MAP-CAC-APPLE'
02:14:33 CR > [switch] Loading table 'MAP-CAC-ORANGE'
02:14:33 CR > [switch] Loading table 'MAP-CLI-MELON'
02:14:33 CR > [switch] Loading table 'IF-LOCAL-BA-precall-service'
02:14:33 CR > [switch] Loading table 'IF-PBX-A-precall-service'
02:14:33 CR > [switch] Loading table 'IF-NODE-B-precall-service'
02:14:33 CR > [switch] Loading table 'IF-NODE-C-precall-service'
node(ctx-cs)[switch]#
02:14:33 CR > [switch] Reloading tables now
02:14:33 CR > [switch] Flushing all tables
02:14:33 CR > [switch] Loading table 'TAB-ISDN-SERVICE'
02:14:33 CR > [switch] Loading table 'TAB-DEST-A'
02:14:33 CR > [switch] Loading table 'CAC-APPLE'
02:14:33 CR > [switch] Loading table 'CAC-ORANGE'
02:14:33 CR > [switch] Loading table 'CLI-MELON'
02:14:33 CR > [switch] Loading table 'MAP-CAC-APPLE'
02:14:33 CR > [switch] Loading table 'MAP-CAC-ORANGE'
02:14:33 CR > [switch] Loading table 'MAP-CLI-MELON'
02:14:33 CR > [switch] Loading table 'IF-LOCAL-BA-precall-service'
02:14:33 CR > [switch] Loading table 'IF-PBX-A-precall-service'
02:14:33 CR > [switch] Loading table 'IF-NODE-B-precall-service'
02:14:33 CR > [switch] Loading table 'IF-NODE-C-precall-service'
node(ctx-cs)[switch]#
Example: Configure SmartNode in an Enterprise Network
Situation:
shows an enterprise network with a SmartNode configured with a BRI port. A PBX, a
LAN, the PSTN, and the company network are connected. The VoIP protocol used is H.323. There is no gate-
keeper, so direct call signaling is used. The voice codec used is G.723, so the DTMF relay is enabled. Because
no special dial tones have to be specified, the default tone-set profile is used.
keeper, so direct call signaling is used. The voice codec used is G.723, so the DTMF relay is enabled. Because
no special dial tones have to be specified, the default tone-set profile is used.
Figure 50. SmartNode in an Enterprise network
Call routing is specified as follows:
•
Calls from office C with number 1xx to office A with a fallback to PSTN
•
Calls from office C with number 2xx to office B with a fallback to PSTN
•
All other calls from office C to PSTN
Node
Company
Backbone
PSTN
PBX
Office A
Office B
Office C
147.86.130.1
147.86.130.24
147.86.130.11
User
2/3
User
2/2
Net
2/1
Net
2/0
clock distribution