Patton electronic SmartNode 4110 Series ユーザーズマニュアル

ページ / 664
ISDN interface configuration task list
394
SmartWare Software Configuration Guide 
34 • ISDN interface configuration
Configuring Call-Hold on ISDN interfaces
Normally, the call-hold feature is disabled on ISDN point-to-point links and enabled on ISDN point-to-mul-
tipoint links. However, you can manually enable or disable the Call-Hold feature using the following com-
mand: The default setting can be achieved using the ‘auto’ configuration option.
Mode: interface isdn
Enabling Display Information Elements on ISDN Ports
By default no display information elements are sent in ISDN signaling messages. You can enable sending of 
ISDN Display Information elements in ISDN signaling messages using the following command.
Mode: interface isdn
Configuring date/time publishing to terminals (optional)
ISDN allows to propagate current time and date information from a port configured as network to the con-
nected terminals. You can configure each ISDN interface to propagate the current SmartNode system time and 
date to the connected terminals with the following command:
Procedure: To configure date and time publishing
Mode: Interface ISDN
Date and time information can only be contained in the ISDN CONNECT message. This message is only 
delivered to a terminal when a call from the terminal to the SmartNode is made, and reaches connected state.
Step
Command
Purpose
1
node(if-isdn)[if-name]# call-hold 
{auto|enable|disable}
Enable or disable the call-hold functionality for 
an isdn interface. If ‘auto’ is selected, call-hold is 
automatically disabled on p2p links and enabled 
on p2mp links.
Default: auto
Step
Command
Purpose
1
node(if-isdn)[if-name]# [no] display 
emit
Enable sending of the display information ele-
ment for an isdn interface.
Default: disabled
Step
Command
Purpose
1
node(if-isdn)[if-name]#[no] isdn-date-time Enable/disable publishing of system time to con-
nected ISDN terminals (default: disabled)