Patton electronic SmartNode 4110 Series ユーザーズマニュアル

ページ / 664
H.323 interface configuration task list
439
SmartWare Software Configuration Guide 
38 • H.323 interface configuration
node(cfg)#context cs
node(ctx-cs)[switch]#interface h323 MyH323If
node(if-h323)[MyH323If]#no status-inquiry
Procedure: To change the default status inquiry interval
Mode: Interface H.323
Example: Disable status inquiries
The following example 
the status inquiry interval for the H.323 interface MyH323If to 120 seconds.
node>enable
node#configure
node(cfg)#context cs
node(ctx-cs)[switch]#interface h323 MyH323If
node(if-h323)[MyH323If]#status-inquiry timeout 120
AOC-D Support for H.323
The H.323 gateway is able to accept and send Advice of Charge during the call (AOC-D) messages according 
to the ITU-T standard Q.956. Facility Information Elements (IEs) in the Q.931 portion of the protocol are 
used to transport AOC-D PDUs.  (Refer to “Chapter 28:  ISDN interface configuration”, section “ISDN 
Advice of Charge support.”)
You can enable/disable reception and transmission of AOC-D messages separately on each H.323 interface. 
When reception is enabled, AOC-D messages received in incoming H.323 FACILITY messages are forwarded 
to the ISDN side of the call. In addition to the H.323 interface, AOC support must also be enabled on the 
ISDN interface (see ISDN Advice Of Charge support section of Chapter 28 ISDN interface configuration of 
the Software Configuration Guide). 
When transmission is enabled, AOC-D messages received from the ISDN side of the call are sent as H.323 
FACILITY to the remote terminal or gatekeeper.
The following commands can be used to change the AOC-D over H.323 tunneling behavior on an H.323 
interface:
Step
Command
Purpose
1
node(if-h323)[if-name]#status-inquiry 
timeout 
seconds
Changes the status inquiry interval on the 
interface to the specified number of seconds