Patton electronic SmartNode 4110 Series ユーザーズマニュアル

ページ / 664
Call router configuration task list
516
SmartWare Software Configuration Guide 
40 • Call router configuration
node(rt-tab)[TEST]#route default dest-interface IF5
node(rt-tab)[TEST]#exit
node(ctx-cs)[switch]#no shutdown
node(ctx-cs)[switch]#debug call-router detail 5
node(ctx-cs)[switch]#test call-router TEST called-e164 123
Parameters
==========
 Time:                                  2004-03-02T16:55:33<-- Time of the lookup
 Result:                                route-found-place-call<-- Lookup result
 Destination:                           IF2<-- Dest. Interface
 Timeout:                               0<-- Digit-Coll. TO
 Property Containers
 -------------------
  Properties
  Properties
   E164-Number:                         123 (String)<-- CdPN after lookup/change
  Properties
16:55:33  CR    > [switch] Routing-Lookup:
16:55:33  CR    >   Find best-matching called-element in table test
16:55:33  CR    >     01: Prefix Timeout Expression: E164-Number of 123 completely 
(no timeout) matches 1
16:55:33  CR    >     02: Prefix Timeout Expression: E164-Number of 123 completely 
(no timeout) matches 1[0-4]
16:55:33  CR    >     03: Prefix Timeout Expression: E164-Number of 123 does not 
match 11
16:55:33  CR    >     04: Prefix Timeout Expression: E164-Number of 123 does not 
match 111
16:55:33  CR    >     Selecting entry 2
16:55:33  CR    >   Execute all elements in table IF2
16:55:33  CR    >   Execute all elements in table route-found-place-call
16:55:33  CR    >   Lookup result: Route found; place call (timeout=0)