Patton electronic SmartNode 4110 Series ユーザーズマニュアル

ページ / 664
Debugging call signaling
631
SmartWare Software Configuration Guide 
52 • VoIP debugging
ISDN port status using the 
show port isdn
 command, and the 
debug isdn events
 commands (see 
below).
Because the ALERTING is indication enough that the signaling is working, we drop the call from the com-
mand line: 
unit(cfg)#call 123456 drop
The interface then sends a DISCONNECT message to the line, and the PSTN answers with a RELEASE 
COMPLETE
Verify ISDN layer 2 and 3 status
ISDN layer 2 and 3 can be verified using a 
show 
command:
node(cfg)#show port isdn 0 2 status
Logical Isdn Driver: 0 0
========================
  Slot:                                 0
  Number of Ports:                      5
  Statistics
  ----------
    Leased buffers:                     24
    Max. leased buffers:                34
    Next Call Key:                      0
  Logical Port: 0 0 2
  -------------------
    Admin State:                        Open
    Real State:                         Open
    Operating Layer:                    3
      Link State:                       up
    Layer 2
      Permanent Layer 2:                off
      Protocol:                         PointToMultiPoint
      UniSide:                          Net
    Layer 3
      Protocol:                         Dss1
      UniSide:                          Net
      MinChannel:                       0
      MaxChannel:                       1
      MaxCalls:                         2
      Hunt Mode:                        Ascending
      Signalling Mode:                  Etsi
The line “link state: up” tells you that layer 1 is up. To debug the layers 2-3 state machines, use the command 
debug isdn event slot port {all | layer2 | layer3}.