Mitsubishi Electronics QD75MH1 ユーザーズマニュアル

ページ / 838
 
 
 
5 - 82 
MELSEC-Q
 
5   DATA USED FOR POSITIONING CONTROL 
 
 
 
 
 
Item  2 Setting 
details 
Setting value 
 
7: Droop pulses 
(   10V/1 x 10
3
[PLS]) 
(Note-1)
   
8: Droop pulses 
(   10V/1 x 10
4
[PLS]) 
(Note-1)
   
9: Droop pulses 
(   10V/1 x 10
5
[PLS]) 
(Note-1)
   
A: Feedback position 
(   10V/1 x 10
6
[PLS]) 
(Note-1)
 
(Note-3)
 
 
B: Feedback position 
(   10V/1 x 10
7
[PLS]) 
(Note-1) 
(Note-3)
 
 
C: Feedback position 
(   10V/1 x 10
8
[PLS]) 
(Note-1) 
(Note-3)
 
 
Pr.172  
(PC09) 
Analog monitor output 1 
Used to set the output signal from analog monitor 
output 1 of the servo amplifier. 
(Note-1): Encoder pulse unit. 
(Note-2): 8V is outputted at the maximum torque. 
(Note-3): It can be used by absolute position 
detection system. 
D: Bus voltage 
(   8V/400[V]) 
 
0: Servomotor speed  
(   8V/max. speed) 
 
1: Torque 
(   8V/max. torque) 
(Note-2)
 
 
2: Servomotor speed  
( + 8V/max. speed) 
 
3: Torque 
( + 8V/max. torque) 
(Note-2)
 
 
4: Current command 
(   8V/max. current 
command) 
 
5: Speed command 
(   8V/max. speed) 
 
6: Droop pulses 
(   10V/1 x 10
2
[PLS]) 
(Note-1)
   
7: Droop pulses 
(   10V/1 x 10
3
[PLS]) 
(Note-1)
   
8: Droop pulses 
(   10V/1 x 10
4
[PLS]) 
(Note-1)
   
9: Droop pulses 
(   10V/1 x 10
5
[PLS]) 
(Note-1)
   
A: Feedback position 
(   10V/1 x 10
6
[PLS]) 
(Note-1)
 
(Note-3)
 
 
E
xpans
ion s
et
ting 
Pr.173  
(PC10) 
Analog monitor output 2 
Used to set the output signal from analog monitor 
output 2 of the servo amplifier. 
(Note-1): Encoder pulse unit. 
(Note-2): 8V is outputted at the maximum torque. 
(Note-3): It can be used by absolute position 
detection system. 
B: Feedback position 
(   10V/1 x 10
7
[PLS]) 
(Note-1) 
(Note-3)