Mitsubishi Electronics QD75MH1 ユーザーズマニュアル

ページ / 838
 
 
 
8 - 15 
MELSEC-Q
 
8   OPR CONTROL 
 
 Operation timing and processing time of fast OPR  
 
The following shows details about the operation timing and time during fast OPR. 
 
t1
t3
t2
In position control
Standing
by
Standing by
Positioning start
signal
BUSY signal
Start complete signal
Positioning operation
Md.26 Axis operation status   
[Y10,Y11,Y12,Y13]
[X10,X11,X12,X13]
[XC,XD,XE,XF]
 
Fig. 8.11 Operation timing and processing time of fast OPR 
 
 
Normal timing time                                             Unit: ms 
 
t1 t2 t3 
1.0 to 1.3 
3.0 to 4.4 
0 to 1.8 
 
The t1 timing time could be delayed by the operation state of other axes. 
 
 Operating restrictions 
 
When the OPR complete flag (
Md.31
 Status: b3) is ON, executing a fast OPR start 
will result in an "Home positioning return (OPR) request flag ON" error (error code: 
207)".