Mitsubishi Electronics QD75MH1 ユーザーズマニュアル

ページ / 838
 
 
 
9 - 42 
MELSEC-Q
 
9   MAJOR POSITIONING CONTROL 
 
[2]   4-axis linear interpolation control (INC linear 4) 
 
 Operation chart 
 
In the incremental system 4-axis linear interpolation control, using an address 
established by a machine OPR in the 4-axis coordinate plane, a linear interpolation 
positioning is carried out from the current stop position (start point address) to a 
position at the end of the movement amount set in the "
Da.6
 Positioning 
address/movement amount". The movement direction depends on the sign (+ or -) 
of the movement amount. 
 
 Restrictions 
 
An error will occur and the positioning will not start in the following cases. The 
machine will immediately stop if the error is detected during a positioning 
operation.  
  When the movement amount for each axis exceeds "1073741824 (=2
30
)" 
An "outside linear movement amount range error (error code: 504)" will occur at 
the positioning start. 
(The maximum movement amount that can be set in "
Da.6
 Positioning 
address/movement amount" is "1073741824 (=2
30
)".)