Mitsubishi Electronics QD75MH1 ユーザーズマニュアル

ページ / 838
 
 
 
12 - 95 
MELSEC-Q
 
12   CONTROL SUB FUNCTIONS 
 
(2) Block start 
At a block start, this function is valid for only the position control whose 
operation pattern is "Positioning complete" at the point whose shape has 
been set to "End". (Refer to Fig. 12.52.) 
 
The following table indicates the operation of the deceleration start flag in the 
case of the following block start data and positioning data. 
 
Block start 
data 
 Da.11   
Shape 
 Da.12   
Start data No. 
 Da.13   
Special start 
instruction 
1st point 
1: Continue 
0: Block start 
2nd point 
1: Continue 
0: Block start 
3rd point 
0: End 
0: Block start 
 
 
 
 
 
 
 
 
 
Positioning 
Data No. 
 Da.1  
Operation pattern 
01: Continuous positioning control 
00: Positioning complete 
00: Positioning complete 
11: Continuous path control 
00: Positioning complete 
 
 
 
 
 
t
1st point: Continue (1)
3rd point: End (0)
2nd point: Continue (1)
Operation 
pattern
Continuous path 
control (11)
Positioning 
data No. 4
Positioning 
data No. 5
Positioning complete (00)
Continuous 
positioning 
control (01)
Positioning 
data No. 1
Positioning 
data No. 2
Positioning complete (00)
Positioning 
data No. 3
Positioning complete (00)
V
Md.48 Deceleration start flag 0
1
 
Fig. 12.52 Operation of deceleration start flag at block start