Mitsubishi Electronics QD75MH1 ユーザーズマニュアル

ページ / 838
 
 
 
Appendix - 50 
MELSEC-Q
 
APPENDICES 
 
(6)   Input/output signal comparisons 
 
Input signal comparisons 
 
QD75M† QD75MH† 
Name 
Logic (initial status) 
Logic switch with 
parameters 
Logic (initial status) 
Logic switch with 
parameters 
In-position 
signal 
– – – – 
Manual pulse generator A phase 
Manual pulse generator B phase  1 
Negative logic 
(multiple of 4) 
Possible 
Negative logic 
(multiple of 4) 
Possible 
Near-point signal 2 
Negative logic 
Possible 
Negative logic 
Possible 
Forced stop input signal 2 
– 
– 
Negative logic 
Not possible 
Stop signal 
Negative logic 
Possible 
Negative logic 
Possible 
Upper limit signal 2 
Negative logic 
Possible 
Negative logic 
Possible 
Lower limit signal 2 
Negative logic 
Possible 
Negative logic 
Possible 
External start 
Negative logic 
Possible 
Negative logic 
Possible 
Speed-position switching signal 
Negative logic 
Possible 
Negative logic 
Possible 
 
1: Comparisons about manual pulse generator A phase/B phase. 
 
 QD75M† QD75MH† 
No. of connectable manual pulse 
generators 
1 generator/1 module 
Mode selection (with parameter) 
Possible 
Multiple of 1 mode, multiple of 2 mode, multiple of 4 mode, PLS/SIGN mode 
 
2: In the case of the QD75MH†, the input signal of "Near-point dog signal" and "Upper/lower limit signal" can be used by setting "Detailed 
parameters 1" (  Pr.80  External signal selection) .