Mitsubishi Electronics QD75MH1 ユーザーズマニュアル
10 - 11
MELSEC-Q
10 HIGH-LEVEL POSITIONING CONTROL
10.3.4 Wait start
In a "wait start", the "condition data" conditional judgment designated in "
Da.14
Parameter" is carried out for the positioning data set in "
Da.12
Start data No.". If the
conditions have been established, the " block start data" is executed. If the conditions
have not been established, the control stops (waits) until the conditions are
established.
have not been established, the control stops (waits) until the conditions are
established.
Section [2] shows a control example where the " block start data" and "positioning
data" are set as shown in section [1].
data" are set as shown in section [1].
[1] Setting examples
(1) Block start data setting example
Axis 1 block
start data
Da.11
Shape
Da.12
Start data No.
Da.13
Special start
instruction
Da.14
Parameter
1st point
1: Continue
1
2: Wait start
3
2nd point
1: Continue
10
0: Block start
–
3rd point
0: End
50
0: Block start
–
•
•
The "condition data Nos." have been set in " Da.14 Parameter".
(2) Positioning data setting example
Axis 1 position-
ing data No.
Da.1
Operation pattern
1
01: Continuous positioning control
2
01: Continuous positioning control
3
00: Positioning complete
•
10
11: Continuous path control
11
11: Continuous path control
12
00: Positioning complete
•
50
00: Positioning complete
•
[2] Control examples
The following shows the control executed when the " block start data" of the 1st
point of axis 1 is set as shown in section [1] and started.
point of axis 1 is set as shown in section [1] and started.
<1> The conditional judgment set in "condition data No. 3" is carried out before
execution of the axis 1 "positioning data No. 1".
Conditions established Execute positioning data No. 1, 2, and 3
Go to <2>.
Conditions not established Control stops (waits) until conditions are
established Go to <1>.
<2> Execute the axis 1 "positioning data No. 10, 11, 12, and 50" and stop the
control.